Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 193
020 - Flow Max - Flow Upper Limit Violation
Figure 161: Warning 020-FM Flow Upper Limit
This warning appears at the submaster whenever the measured
flow is more than the expected flow (upper limit failure).
"SAT=" lists the address(es) of any satellites which were
irrigating at the time of the warning.
Example: Assume a submaster address of 01-00. If the warning
reads "SAT=2,5 GPM=420" then satellites 01-02,
01-05 had irrigating stations and the sum of their
measured flow was 420 GPM.
Action:
Step 1 Examine the warnings at the listed satellites to
determine which stations were on at the time of the
warning. Each satellite will have an "FM STATION
ADVANCE" warning. This warning indicates
which stations were on at the time the submaster
detected the "FLOW UP LIM" violation.
Step 2 Check for:
a. Stuck valve (from previous station)
b. Broken pipes/heads
c. Incorrectly established individual station limits
d. Large variations in system water pressure
Step 3 IMPORTANT:
Upon resolution of the problem, CLEAR all
warnings at all satellites. If warnings are not
cleared, the stations will remain off indefinitely.